您現在所在位置:首頁 > 產品中心 > 高低壓開關櫃 > 高壓開關櫃 > KYN61-40.5手車式高壓開關櫃安裝方式

KYN61-40.5手車式高壓開關櫃安裝方式

產品型號:
所屬分類:高壓開關櫃
KYN61A-40.5 開關設備配置性能優良的ZN85A,ZN85B真空斷路器或施耐德公司SF1、SF2或ABB公司HD4或阿爾斯公司FP係列六氟化硫斷路器。櫃體采用組裝結構,提高了外觀質量和製造精度;母線采用熱縮絕緣材料或環氧塗覆的絕緣手段,優化電極形狀,櫃體結構緊湊,並具備完善的“五防"功能。KYN61-40.5手車式高壓開關櫃安裝方式

 

 

A Product Overview

KYN61-40.5 indoor AC metal armoured removable switchgear series (hereinafter referred to as switchgear). Applicable to indoor three-phase 50Hz, rated voltage 35KV, 25KV, 12KV power system. Mainly used in power plants, substations, industrial and mining enterprises and institutions and high-rise buildings, as receiving and distributing energy, and large-scale high-voltage motor start-up. It has the functions of control, protection, detection and so on. It can also be used to control the places where frequent operation takes place.

This switchgear can meet the requirements of GB3906 "3.6 kV-40.5 kV AC metal-enclosed switchgear and control equipment", IEC 60694: 2002 "Common Technical Requirements for High Voltage Switchgear and Control Equipment Standard", DL404-S1 "Technical Conditions for Order of Indoor AC Switchgear Containers", IEC298 and other standards. It also has the functions of preventing misoperation of circuit breakers, preventing live handcarts from being charged; Turn off the grounding switch, prevent the grounding switch from sending electricity when it is in the grounding position, and prevent it from mistakenly entering live isolation.

II. Environmental Conditions for Use

2.1 Altitude: no more than 2000 meters.

2.2 ambient temperature: the upper limit is 40 and the lower limit is - 10 C.

2.3 Relative humidity: the daily average is not more than 95%, and the monthly average is not more than 90%.

2.4 Earthquake Intensity: No more than 8 degrees.

2.5 There is no danger of fire and explosion, no severe pollution such as violent vibration and chemical corrosion.

Note: When exceeding the above environmental conditions, users should consult with the manufacturer.

Three main characteristics

3.1 The structure of cabinet body is made of aluminium-zinc coated sheet bolted by CNC machine tools using multiple bending process.

3.2 All operations are carried out under closed cabinet doors.

3.3 The protective level of the switch cabinet shell reaches IP4X, and the protective level of each compartment is IP2X.

3.4 It has perfect and effective "five preventive" function to prevent misoperation.

3.5 It can be equipped with ZN85-40.5 (3AV3), ZN83A (VS1), VD4 ZN21, 3AH, VB2, VEP vacuum circuit breaker, VC7 vacuum contactor, C3 series fixed load switch and disconnector. With additional communication interface, it can be connected with the mobiles phones of the staff on duty to implement remote control and remote measurement functions.

3.6 It can be equipped with voltage transformer handcart, lightning arrester handcart, metering handcart, isolation handcart, fuse handcart and transformer landing handcart. The handcart of the same specificatin has interchangeability.

3.7 Installation of reliable wall of cabinet body (reserved maintenance channel) and maintenance before cabinet to reduce occupied area.

3.8 Cable room has abundant space and can connect multiple cables.

3.9 Heaters can be installed in circuit breaker room and cable room respectively to prevent condensation and corrosion.

KYN61-40.5手車式高壓開關櫃安裝方式KYN61-40.5手車式高壓開關櫃安裝方式

 

一  產品概述

     KYN61-40.5 型戶內交流金屬鎧裝移開式開關設備係列(以下簡稱開關設備)。適用於戶內三相50Hz,額定電壓35KV、25KV、12KV的電力係統。主要應用於發電廠、變電站、工礦企事業單位及高層建築中,作為接受和分配電能、及大型高壓電動機啟動之用。對電路起到控製、保護、檢測等功能,還可用於控製頻繁操作的場所。

     本開關設備能滿足GB3906《3. 6 kV -40. 5 kV 交流金屬封閉開關設備和控製設備》、IEC 60694: 2002 《高壓開關設備和控製設備標準的共用技術要求》、DL404-S1《戶內交流開關櫃定貨技術條件》、IEC298等標準要求,並且具有防止誤操作斷路器;防止帶負荷拉手車;防止帶電關合接地開關;防止接地開關在接地位置時送電和防止誤入帶電隔離等“五防”功能。

 

二 使用環境條件

2.1 海拔高度:不超過2000米。

2.2 環境溫度:上限為40℃;下限為-10℃。

2.3 相對濕度:日平均值不大於95%,月平均不大於90%。

2.4 地震烈度:不超過8度。

2.5 沒有火災爆炸危險,沒有劇烈震動及化學腐蝕等嚴重汙穢的場所。

注:超出上述環境條件時,用戶應與製造廠協商。

 

三 主要特點

3.1 櫃體結構采用敷鋁鋅板經CNC機床使用多重折彎工藝加工之後栓接而成。

3.2 所有操作均在櫃門關閉狀態下進行。

3.3 開關櫃的外殼防護等級達到IP4X,各隔室的防護等級為IP2X。

3.4 具備完善有效的“五防” 功能,防止誤操作。

3.5 可配用ZN85-40.5(3AV3)、ZN83A(VS1)、VD4 ZN21、3AH、VB2、VEP型真空斷路器,VC7真空接觸器、C3係列固定式負荷開關及隔離開關等。加配通訊接口,可與值班人員手機聯網,實行搖控、搖測功能。

3.6 可配用電壓互感器手車、避雷器手車、計量手車、隔離手車、熔斷器手車、所用變壓器落地手車,相同規格的手車具有互換性。

3.7 櫃體可靠牆安裝(預留檢修通道)、櫃前維護,減少占地麵積。

3.8 電纜室空間充裕、可連接多根電纜。

3.9斷路器室和電纜室可分別加裝加熱器,防止凝露與腐蝕發生。

 